Kryton Smart Concrete® INTEGRAL WATERPROOFING & DURABILITY SOLUTIONS
b
  • English
  • Spanish
  • India
  • China
  • Products
    • Krystol® Technology
    • Smart Concrete®
    • Admixtures & Additives
      • Krystol Internal Membrane™ (KIM®)
      • Hard-Cem®
      • Con-Fume®
      • Krystol Mortar Admixture™ (KMA)
    • Surface Applied Waterproofing
      • Krystol Broadcast™
      • Krystol T1® Concrete Waterproofing
      • Hydrostop™ Sealer
    • Construction Joints & Details
      • Krystol Waterstop Grout™
      • Krystol Waterstop Treatment™
      • Krytonite™ Swelling Waterstop
      • Crack Inducing Waterstop
    • Concrete Repairs
      • Krystol Leak Repair System
      • Krystol Repair Grout™
      • Krystol Bari-Cote™
    • Concrete Monitoring
    • Standard Warranty
    • Krystol Assurance Program™ (KAP)
  • Sectors
    • Buildings
    • Industrial
    • Infrastructure
  • Case Studies
  • Resources
    • Information for Owners/Developers
    • Information for Architects
    • Information for Engineers
    • Information for General Contractors
    • Information for Concrete Producers
    • Technical Info
      • Application Overviews
      • Application Instructions
      • Specifications
      • Technical Data Sheets
      • Safety Data Sheets
      • CAD Drawings
      • Testing & Certification
      • LEED
    • Courses
    • Brochures
    • Videos
  • Sustainability
  • About
    • Why Kryton
    • Leadership
    • Our Values
    • Kryton History
    • Testimonials
    • News
    • Blog
    • Careers
      • Life as Krytonite
      • Current Positions
  • Find a Distributor
  • Regions
    • Spanish – Español
    • India – English
    • China – 简体字

Media

Contact Us

Long term test differentiates corrosion inhibiting admixtures

Media » News June 24, 2013

The corrosion of reinforcing steel has been a growing concern for structures due to the increase in occurrences and the costs of repairs. So how can you know which product is best to do the job of protecting your steel from corroding?

Kryton’s KIM admixture significantly outperforms other chemical admixtures corrosion inhibiting properties.To answer this question, a long-term independent field exposure study was conducted by the University of Hawaii to evaluate the durability of reinforced concrete specimens exposed to an aggressive marine enviromnent. Twenty-five test panels made of concrete and reinforced with steel were exposed to the aggressive, warm salt waters in the tidal zone at Pier 38 in Honolulu Harbor for a period of 9—10 years from 2002 to 2012. This study represents one of the longest continual test periods ever carried out in the world for corrosion of reinforced concrete.

GC_details_062013cIn addition to control specimens, the panels included various corrosion inhibiting admixtures and pozzolans intended to reduce the chloride penetration rates through the concrete and delay the onset of chloride induced corrosion of the reinforcing steel. During exposure, the panels were monitored for half-cell potential, chloride concentrations, cracking and visible signs of corrosion.

The key findings in the reports are as follows:

  • The panel using 2% Kryton’s Krystol Internal Membrane (KIM) outperformed all other chemical admixtures used in the test, showing significantly reduced half-cell reading when compared with the control specimen. Panels using the remaining admixtures, Rheocrete 222+, FerroGard 901, Xypex Admix C—2000 and a latex modifier exhibited inconsistent to poor results.
  • Calcium nitrite based corrosion inhibitors delayed the onset of corrosion at a dose of 20 L/m3, but did not provide reliable protection at a lower dose of 10 L/m3. These admixtures were not effective at reducing the ingress of chlorides.
  • Pozzolans (15% fly ash and 5% silica fume) combined with a reduced water-cement ratio (0.36 compared to other samples batched at 0.40) performed Well, although poor dispersion of the silica fume compromised the ance of at least one panel.
  • Control panels (no admixture or Pozzolan) with a water-cement ratio of 0.40 experienced corrosion—induced cracking
    and rust residue.

Installation of panels at Honolulu HarborLong-term exposure testing is the most accurate form of testing, because the exposure simulates the actual service conditions of a real structure. Laboratory tests are generally short term, and are designed to provide accelerated results using conditions that do not always model real life.

As this study suggests, Krystol Internal Membrane (KIM) admixture differs from other single-function admixtures and supplementary cementitious materials. The combination of reducing the permeability of the concrete, reducing shrinkage cracking, and improving the self-sealing properties can increase the resistance of concrete to the penetration of harmful chemical agents. It is concluded that KIM can prevent corrosion in reinforced concrete by impeding the development corrosive conditions. The result is a structure with increased durability a longer lifespan and lower maintenance costs over the structures service life.

Source: Construction Week Qatar

Subscribe to our eNewsletter

Stay connected and subscribe to get the latest news. You can unsubscribe at any time.

"*" indicates required fields

By submitting the form, you agree to our Terms and Conditions and Privacy Policy

Terms of Use Privacy Policy Distributor Portal
Toll Free: +1.800.267.8280 Tel: +1.604.324.8280 Email us

Corporate Headquarters: 1645 East Kent Avenue, Vancouver, British Columbia, V5P 2S8 Canada

Calgary (Cementec): 13 Industry Way SE, Calgary, Alberta T3S 0A2 Canada

China: Room 1012, Block B, Tongzhou Wanda Plaza, No. 58, Xinhua West Street, Tongzhou District, Beijing

India (Kryton Buildmat Co. Pvt.): 136-137 Centrum Plaza, Golf Course Road, Sector 53, Gurgaon Haryana 122002

©2023 Kryton International Inc.